|
Work Time Mon to Fri :9:00-17:30 Contact Details Mrs.Xie:18874070117 Mr.Xu:13755079320 Fax:0731-89637631 Customer Service:0731-89634887 Mailbox:anna.xie@hn-ecloud.com Address:Liuyang Economic Development Zone, Changsha, Hunan, China |
American FCC CertificationIssuing time:2019-09-02 23:02 American FCC Certification Definition
The full name of FCC certification in the United States is Federal Communications Commission, which was established by COMMUNICATIONACT in 1934 as an independent body of the United States Government and is directly responsible to Congress. FCC coordinates domestic and international communications by controlling radio, television, telecommunications, satellites and cables. It covers more than 50 states, Colombia and areas of the United States to ensure the safety of radio and wire communications products related to life and property. American FCC certification can be divided into two types: FCC-ID certification and FCC-sDOC certification. Scope of FCC Certification Products in USA Federal Communications Commission (FCC) - Manages the import and use of radio frequency devices, including computers, fax machines, electronic devices, radio reception and transmission equipment, radio remote control toys, telephones, personal computers and other products that may harm personal safety. If these products are to be exported to the United States, they must be tested and approved by government-authorized laboratories in accordance with FCC technical standards. Importers and customs agents are required to declare that each radio frequency device meets the FCC standard, that is, the FCC license. 1. Power FCC certification: communication power supply, switching power supply, charger, display power supply, LED power supply, LCD power supply, UPS, etc. 2. FCC certification of lamps and lanterns: chandelier, track lamp, yard lamp, portable lamp, tube lamp, LED street lamp, lamp string, desk lamp, LED spotlight, LED bulb lamp, grid lamp, aquarium lamp, street lamp, LED lamp, LED lamp, energy-saving lamp, T8 lamp tube, etc. 3. Household appliances FCC certification: fans, electric kettles, audio, television, mouse, vacuum cleaner, etc. 4. Electronic FCC certification: earplugs, routers, cell phone batteries, laser pens, vibration rods, etc. 5. FCC Certification of Communication Products: Telephone, Cable Telephone Wireless Main and Secondary, Fax Machine, Telephone Recorder, Data Machine, Data Interface Card and Other Communication Products. 6. FCC certification of wireless products: Bluetooth BT products, tablet computers, wireless keyboards, wireless mice, wireless readers, wireless transceivers, wireless walkie-talkies, wireless microphones, remote controllers, wireless network devices, wireless image transmission systems and other low-power wireless products; 7. FCC certification of wireless communication products: 2G mobile phone, 3G mobile phone, 3.5G mobile phone, DECT mobile phone (1.8G, 1.9G band), wireless walkie-talkie, etc. 8. Mechanical FCC Certification: Gasoline Engine, Welding Machine, CNC Drilling Machine, Tool Grinder, Mower, Washing Equipment, Bulldozer, Lift, Drilling Machine, Dishwasher, Water Treatment Equipment, Gasoline Welding Machine, Printing Machine, Woodworking Machine, Rotary Drilling Machine, Weedging Machine, Snow Sweeper, Excavator, Printer, Printer, Cutting Machine Machine, roller, smoother, mower, hair straightener, food machinery, lawn machine, etc. American FCC Certification Testing Contents The technical reports compiled to the FCC include the performance indicators of RF output power, modulation characteristics, bandwidth occupied, spurious emission from antenna ports, spurious radiation field strength, frequency stability and spectrum characteristics. The FCC regulations stipulate in principle the limits and test requirements of each performance indicators, and only for the corresponding ones. The test method is briefly introduced. Radio Frequency Output Power According to the power regulation program, the voltage and current values fed into the RF amplifier circuit are adjusted to make it in the maximum rated power transmission state, and the appropriate load is added to the RF output port to test the maximum RF output power. The method of power regulation will be different for different types of transmission, which should be explained in detail in the technical report. Modulation characteristics (1) For voice modulation communication products, the frequency response curve of the audio modulation circuit should be measured in the frequency range of 100-5000Hz. If the product uses an audio low-pass filter, the frequency response curve of the audio filter should also be measured. (2) For products with modulation limitation processing, the relationship curve between the modulation percentage and the input voltage in the whole modulation frequency and signal power level should be determined. (3) For single sideband and independent sideband radio telephone transmitters with limited peak envelope power circuits, the relationship curve between peak envelope output power and input voltage should be measured. (4) Other types of products will be processed according to the type of certification applied and the corresponding regulations. Occupy bandwidth When measuring the occupied bandwidth, the measurement methods will be different for products with different modulation modes. However, the basic principle is to select the largest modulation signal in typical service modes for testing, and the input modulation signal is described in detail in the report. Spurious emission from antenna ports In addition to the RF power or voltage at the useful frequency point of the product, it is necessary to measure the useless spurious frequency. When measuring, a suitable false antenna can be added to the output port of the antenna; harmonics and some prominent spurious emission points need to be paid more attention. Stray radiation field intensity This test mainly detects the harmonics of the shell port, the control circuit module and the power port of the product and the field strength of some prominent spurious radio frequency points. For products operating at frequencies below 890MHz, measurements need to be carried out in an open field or anechoic chamber. For on-site testing, it is necessary to make a detailed investigation and analysis of the RF source near the measurement site and the obvious reflective objects. Frequency stability The frequency stability that needs to be examined includes the frequency determination of the product and the frequency variation of the stabilizing circuit when the ambient temperature and input voltage change. In special cases, it may also include the frequency stability of the product when it is equipped with different antennas or moves near larger metal objects. The range of temperature change is - 30 ~50 C, and the temperature interval measured is not more than 10 C. When measuring the frequency of each temperature point, it is necessary to wait long enough for the components related to the resonant circuit to reach a stable state. Voltage variations range from 85% to 115% of the rated operating voltage. For portable products that rely on batteries, the lowest voltage can be the cut-off voltage. Spectrum characteristics The spectrum range of stray emission and radiation field intensity evaluation and measurement will be determined according to the working frequency of the product. The lowest frequency of spectrum characteristic research can choose the lowest frequency point which the product actually uses; if the lowest frequency is lower than 9kHz, 9kHz is chosen as the lowest frequency point of research. The selection of the highest frequency follows the following principles: (1) For products with operating frequency below 10 GHz, the highest fundamental frequency of 10 harmonics is selected as the highest frequency of evaluation. If the frequency of 10 harmonics is greater than 40 GHz, 40 GHz is chosen as the highest frequency of evaluation. 2) For products with operating frequencies between 10 GHz and 30 GHz, the fifth harmonic of the highest fundamental frequency is selected as the highest frequency of evaluation. If the frequency of the fifth harmonic is greater than 100 GHz, the 100GHz is chosen as the highest frequency of evaluation. (3) For products with operating frequencies above 30 GHz, the highest fundamental frequency of the 5th harmonic is chosen as the highest frequency of the evaluation. If the frequency of the 5th harmonic is greater than 200 GHz, the 200GHz is chosen as the highest frequency of the evaluation. |